Olympus FluoView FV 3000RS IX83 Inverted Confocal Microscope
Capabilities
- Imaging diverse fluorophores in fixed or live samples
- Temperature, humidity, CO2 control
- Spectrally tunable detectors
- Ultra-fast resonant scanning (reduced photo-damage with live samples)
- 3D z-stacks, timelapse, multi-position timelapse
Microscope
- Olympus IX83 fully motorized inverted microscope
- Zero Drift Compensator (IX3-ZDC2) laser-based autofocus
- Ultrasonic automated stage and multiple area time lapse stage control software, as well as well-plate navigator tool for multi-area, time-lapse, and multi-area mosaic image stitching
- Tokai hit stage top, live-cell incubation chamber
- Analog and digital in-out box for synchronization with external devices
Tandem Scanners
- Conventional scanner for high-definition imaging
- Resonant scanner for high-speed imaging (capable of 30 FPS@512×512 and 438 FPS@512×32)
Light Sources
- All Diode Lasers with 4 Laser Lines–405 nm, 488 nm, 561 nm and 640 nm
- LED-based transmitted and epifluorescence illumination
Conventional Fluorescence Filters
- Dapi
- Green
- Red
Objectives
Air objectives:
- UPLSAPO10X2
- UCPLFLN20X,
- UPLSAPO40X2
- UAPON100XOTIRF; UAPON 100X TIRF, NA 1.49,
Silicone oil objectives:
- UPLSAPO30XS; UPLSAPO N 30X SI OIL, NA 1.05,WD 0.8MM, W/CC (with correction collar)
- UPLSAPO60XS; UPLSAPO N 60X SI OIL, NA 1.30, WD 0.3MM,W/CC
Nomarski Differential Interference contrast capability on 10x, 20x, 30x, 40x, 60x, 100x.
Computer and Software
- HP Windows 7 64bit Confocal Workstation and 30” Monitor
- Complete Fluoview Acquisition & Analysis Software provides FRAP, FRET, Ratiometric Imaging Display & Analysis, 3D Image Acquisition & Display, Live 16 Channel Spectral Unmixing, Fluorescence Intensity Measurements, Time-Lapse Imaging, and More…
- Olympus cellSens Dimension provided for additional post-acquisition data analysis and processing
- Includes Olympus cellSens Count & Measure Solution for threshold-based object detection as well as automatic object measurement and classification
Includes Olympus cellSens 3D Deconvolution Solution utilizing Constrained Iterative Deconvolution algorithm for improved resolution, contrast and dynamic range.
Detectors
- 4 High-Sensitivity Peltier-Cooled GaAsP Spectral Confocal Detectors with Olympus TruSpectral High-Efficiency Volume Phase Hologram spectral detection system (1-100 nm adjustable emission bandwidth with 2 nm spectral resolution)
- Transmitted light detector for Brightfield/DIC Image Acquisition